UPS 2U

UniFi managed 1.44kVA rackmount uninterruptible power supply with 4 backup outlets, 4 surge outlets, and a field replaceable battery, 216Wh, half load (500W) runtime of 8 minutes. Supports Graceful Shutdown for UNVR and UNAS, and includes NUT compatibility for third-party devices. Note. For Graceful Shutdown functionality, UniFi OS version 4.4.3 or higher is required.

Networking & Wi-Fi product — UBNT-CATALOG-UPS-2U-US

Product overview

UniFi managed 1.44kVA rackmount uninterruptible power supply with 4 backup outlets, 4 surge outlets, and a field replaceable battery, 216Wh, half load (500W) runtime of 8 minutes. Supports Graceful Shutdown for UNVR and UNAS, and includes NUT compatibility for third-party devices. Note. For Graceful Shutdown functionality, UniFi OS version 4.4.3 or higher is required.

Key details

BrandUbiquiti

Manufacturer modelUPS-2U

InstallationQuoted separately

Dimensions442.4 x 300 x 87.4 mm (17.4 x 11.8 x 3.4")

Weight14 kg (30.9 lb)

Enclosure MaterialGalvanized steel

Form FactorRack mount (2U)

WeatherproofingIP20

ManagementEthernet

Networking Interface(1) 100/10 MbE port for network connection (2) GbE ports for surge in/out

Power(1) OVC II AC in: NEMA 5‑15P, 1.8 m (5.9 ft) non-removable power cord (4) Battery backup/surge protection: NEMA 5‑15R (4) Surge protection: NEMA 5‑15R

Capacity1,440VA/1,000W

TypeLine interactive

Input Voltage Range89–145V AC

Power Method(1) TN system, 120V AC, 12A Max., 50/60 Hz

Nominal Input Voltage120V AC

Output Voltage120V AC

Frequency RangeAC mode: 50/60 Hz ±5 Hz (Auto sensing) Battery mode: 60 Hz ±1 Hz

AC Voltage Regulation±10% (Battery mode)

Transfer Time6 ms typical; 10 ms max. (Battery mode)

Wave FormSimulated sine wave (Battery mode)

Battery Type(2) Lead Acid 12V, 9Ah

RuntimeFull load: 2.3 min Half load: 8 min

Battery Charging Time6-8 hours recovery to 90% capacity

Overload at On-Line Mode110% 5 min go to fault 120% go to fault immediately

Overload at Battery Mode110% shutdown in 5 sec 120% shutdown immediately

Short Circuit Protection at On-Line ModeBreaker, 250V AC, 15A

Output Short-Circuit CurrentIpeak 348.0A Irms 115.1A

Buttons(1) Power (1) Factory reset

StatusOff: device not turned on Flashing white: initializing / factory default Steady white: waiting for adoption Steady blue: device adoption and working Flashing blue: battery mode Alternating white/blue: firmware upgrading Rapid flashing blue: locate Steady red: warning Flashing red: low battery

Operating Altitude3,000 m (1.9 mi)

Operating EnvironmentPollution Degree 2

Ambient Storage Temperature-20 to 50° C (-4 to 122° F)

Ambient Operating Temperature0 to 40° C (32 to 104° F)

Ambient Operating Humidity0 to 95% noncondensing

CertificationsFCC, IC, UL 1778, CSA C22.2 No. 107.3