Access Retrofit Hub
DC-powered hub that supports Wiegand and OSDP readers and provides entry and exit control for up to two doors.

Product overview
DC-powered hub that supports Wiegand and OSDP readers and provides entry and exit control for up to two doors.
Key details
BrandUbiquiti
Manufacturer modelUA-Retrofit-Hub-2
InstallationQuoted separately
Additional Inputs2 Additional Inputs
Lock Terminals2 Lock Terminals
AUX Terminals2 AUX Terminals
Dimensions140 x 120 x 45 mm (5.5 x 4.7 x 1.8")
Supported Doors2
Maximum User Count10,000
Input Terminals(2) Third-party Wiegand Reader / UniFi Retrofit Reader (2) Door exit request (2) Door position (1) Emergency
Power Method12/24V DC
UL 294 LevelDestructive attack: Level I Line security: Level I Endurance: Level I Standby power: Level I
Weight420 g (14.8 oz)
Enclosure MaterialPolycarbonate
Mount MaterialSGCC steel
MountingDin-rail (Included)
Digital Input(2) Third-party Wiegand Reader / UniFi Retrofit Reader (2) Door exit request (2) Door position (1) Emergency
Dry Output RelayLock: rated 30V DC, up to 1A Aux: rated 30V DC, up to 1A
Powered Output Relay12V Lock: 12V DC, up to 1A 24V Lock: 24V DC, up to 0.5A
Indoor and Outdoor UseIndoor only
Ambient Operating Temperature-10 to 40° C (14 to 104° F)
Ambient Operating Humidity5 to 90% noncondensing
Networking Interface(2) 10/100 MbE RJ45 ports
Power SupplyDC 12/24V
Max. Power Consumption50W
Reader Power Output12V DC, up to 0.5A
LEDsW/B Learn More
Buttons(1) Factory reset (2) 12V/Dry/24V switch
UA-Retrofit-Reader (250mA)18 UACC-Cable-DoorLockRelay length: 152.4 m (500 ft)
UA-Lock-Electric (400mA)24 AWG length: 25 m (82 ft) 22 AWG length: 42 m (138 ft) 20 AWG length: 66 m (217 ft) 18 UACC-Cable-DoorLockRelay length: 100 m (328 ft)
UA-Lock-Magnetic-540kg (500mA)24 AWG length: 20 m (66 ft) 22 AWG length: 32 m (105 ft) 20 AWG length: 51 m (167 ft) 18 UACC-Cable-DoorLockRelay length: 80 m (262 ft)
UA-Lock-Magnetic-270kg (800mA)24 AWG length: 12 m (39 ft) 22 AWG length: 20 m (66 ft) 20 AWG length: 30 m (98 ft) 18 UACC-Cable-DoorLockRelay length: 46 m (151 ft)
Other locks (1A)24 AWG length: 9 m (30 ft) 22 AWG length: 15 m (49 ft) 20 AWG length: 24 m (79 ft) 18 UACC-Cable-DoorLockRelay length: 36 m (118 ft)
PoE Cabling RequirementsCat 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site. The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm² ) for patch cords; 24 AWG (0.21 mm² ) for horizontal or riser cable.
UL 294 StatementCompliance with IEEE 802.3 specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
CAN/ULC-60839-11-1 GradeGrade assignment: I
CertificationsCE, FCC, IC, UL 294, CAN/ULC-60839-11-1
Document number, and issue date and/or revision levelUA-Retrofit-Hub-2, V01
Management ApplicationAccess
Software InformationThe software version can be checked at https://unifi.ui.com
Equipment price$327.60
Highlights
- Equipment only; installation is quoted separately
- Select the required configuration before ordering
Additional manufacturer documents
- Official product details · Manufacturer website
- Installation guide · Manufacturer website