EquipmentDoor access control · Ubiquiti
Access Button
Includes black and white faceplates
Selected equipment price$50.70

Image 1 of 6Product view
DC-powered hub that supports Wiegand and OSDP readers and provides entry and exit control for up to two doors.
DC-powered hub that supports Wiegand and OSDP readers and provides entry and exit control for up to two doors.
| Highlight 1 | Equipment only; installation is quoted separately |
|---|---|
| Highlight 2 | Select the required configuration before ordering |

| Brand | Ubiquiti |
|---|---|
| Manufacturer model | UA-Retrofit-Hub-2 |
| Installation | Quoted separately |
| Additional Inputs | 2 Additional Inputs |
| Lock Terminals | 2 Lock Terminals |
| AUX Terminals | 2 AUX Terminals |
| Dimensions | 140 x 120 x 45 mm (5.5 x 4.7 x 1.8") |
| Supported Doors | 2 |
| Maximum User Count | 10,000 |
|---|---|
| Input Terminals | (2) Third-party Wiegand Reader / UniFi Retrofit Reader (2) Door exit request (2) Door position (1) Emergency |
| Power Method | 12/24V DC |
| UL 294 Level | Destructive attack: Level I Line security: Level I Endurance: Level I Standby power: Level I |
| Weight | 420 g (14.8 oz) |
| Enclosure Material | Polycarbonate |
| Mount Material | SGCC steel |
| Mounting | Din-rail (Included) |
| Digital Input | (2) Third-party Wiegand Reader / UniFi Retrofit Reader (2) Door exit request (2) Door position (1) Emergency |
| Dry Output Relay | Lock: rated 30V DC, up to 1A Aux: rated 30V DC, up to 1A |
| Powered Output Relay | 12V Lock: 12V DC, up to 1A 24V Lock: 24V DC, up to 0.5A |
| Indoor and Outdoor Use | Indoor only |
| Ambient Operating Temperature | -10 to 40° C (14 to 104° F) |
| Ambient Operating Humidity | 5 to 90% noncondensing |
| Networking Interface | (2) 10/100 MbE RJ45 ports |
| Power Supply | DC 12/24V |
| Max. Power Consumption | 50W |
| Reader Power Output | 12V DC, up to 0.5A |
| LEDs | W/B Learn More |
| Buttons | (1) Factory reset (2) 12V/Dry/24V switch |
| UA-Retrofit-Reader (250mA) | 18 UACC-Cable-DoorLockRelay length: 152.4 m (500 ft) |
| UA-Lock-Electric (400mA) | 24 AWG length: 25 m (82 ft) 22 AWG length: 42 m (138 ft) 20 AWG length: 66 m (217 ft) 18 UACC-Cable-DoorLockRelay length: 100 m (328 ft) |
| UA-Lock-Magnetic-540kg (500mA) | 24 AWG length: 20 m (66 ft) 22 AWG length: 32 m (105 ft) 20 AWG length: 51 m (167 ft) 18 UACC-Cable-DoorLockRelay length: 80 m (262 ft) |
| UA-Lock-Magnetic-270kg (800mA) | 24 AWG length: 12 m (39 ft) 22 AWG length: 20 m (66 ft) 20 AWG length: 30 m (98 ft) 18 UACC-Cable-DoorLockRelay length: 46 m (151 ft) |
| Other locks (1A) | 24 AWG length: 9 m (30 ft) 22 AWG length: 15 m (49 ft) 20 AWG length: 24 m (79 ft) 18 UACC-Cable-DoorLockRelay length: 36 m (118 ft) |
| PoE Cabling Requirements | Cat 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site. The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm² ) for patch cords; 24 AWG (0.21 mm² ) for horizontal or riser cable. |
| UL 294 Statement | Compliance with IEEE 802.3 specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits. |
| CAN/ULC-60839-11-1 Grade | Grade assignment: I |
| Certifications | CE, FCC, IC, UL 294, CAN/ULC-60839-11-1 |
| Document number, and issue date and/or revision level | UA-Retrofit-Hub-2, V01 |
| Management Application | Access |
| Software Information | The software version can be checked at https://unifi.ui.com |
Review printable model details and manufacturer documentation before ordering.
These recommendations prioritize useful companion categories for this equipment—not a generic catalog list.
Equipment
Equipment
Equipment
Equipment
Equipment
Equipment
Equipment
Equipment
Equipment
Equipment
Equipment
EquipmentLoading reviews…
Sign in to write a review or vote on helpful reviews.
Equipment
Equipment
Equipment
Equipment
Equipment
Equipment
Equipment
Equipment
Equipment
Equipment
Equipment
Equipment
Equipment
Equipment
Equipment
Equipment
Equipment
Equipment
Equipment
Equipment
Equipment
Equipment
Equipment
Equipment